Location of machine rooms and control rooms.
Elevator machine room sign requirements.
2 elevator machine room control room and control space access doors shall be provided with a sign that reads elevator equipment room authorized personnel.
7 amend subdivision a of rule 101 5 to read as follows.
A permanent sign shall be mounted on the head jamb of the main floor elevator entrance which shall read mrl control room located on floor with the applicable floor.
4 elevator machine rooms or enclosed areas shall be kept free of all materials except those used for repair or maintenance of the elevator.
Machine rooms and machinery space.
Machine room doors shall be labeled elevator machine room with letters not less than two 2 inches 51 mm high.
After the last sentence add.
8 amend subdivision c of rule 101 5 to read as follows.
Get it as soon as fri sep 11.
Electrical wiring pipes and ducts in hoistways and machine rooms.
Elevator machine room authorized personnel only sign 14x10 inch aluminum for elevator escalator by compliancesigns.
For machine rooms and control rooms with double swing doors the doors shall swing out and the switch es shall be located on the wall adjacent to the hinge side of the active door panel.
Elevator safety is a critical consideration for builders who have state safety codes to follow permits to obtain and regular inspections to pass.
Location of machinery spaces machine rooms control spaces control rooms and equipment 2 7 6 1.
2 27 3 1 5 all fire recall switches shall be pro vided with an illuminated visual signal to indicate when phase i emergency recall operation is in effect.
Equipment in machine rooms spaces.
Machine rooms shall be kept reasonably clean.
Control room must be of adequate size to provide clearances around and between equipment as required by code.
By the elevator or in the hoistway or in an elevator machine room or a control space or a control room see 2 27 3 2 shall initiate phase i emergency recall operation.
Elevator machine room sign 12x12 rust free heavy aluminum uv protected long lasting weather fade resistant easy mounting indoor outdoor use made in usa.
Provide a fused disconnect switch for each elevator in the control room located in a position based on local code and within sight of elevator equipment and arranged to be locked in the off position.
In traction elevator machine rooms install a beam above the elevator machine and motor that is sufficient in size and capacity to support the removal of elevator equipment.
Size and configure the elevator machine room so that there is a minimum clearance of 18 between any building component and a traction elevator drive machine.
Control switch shall be located on the lock jamb side of the access door.