Cws series 50 hz.
Fan coil unit above ceiling.
As illustrated in the above image.
These will condition.
Coming off the supply duct is a round duct supplying the fan coil units.
They are used in some office buildings and shopping centres and typically specified where there are multiple small spaces requiring individual control.
A fan coil unit fcu also known as a vertical fan coil unit vfc is a device consisting of a heat exchanger coil and a fan as part of an hvac system found in residential commercial and industrial buildings a fan coil unit is often connected to ductwork and a thermostat to regulate the temperature of one or more spaces.
When a fan coil unit is located above a t bar ceiling the noise it generates is difficult to control even with lined ductwork or silencers.
600 to 3 000 cfm.
The air comes out of the fcu either cooler or hotter than before.
The concealed ceiling fan coils and ducted air handler units shown above are meant to be specified and installed only by a professional hvac contractor.
The 42c units are designed to occupy a minimum space using furred in painted cabinet or telescoping bottom panel models.
42df ceiling with exposed cabinet.
The cpy design enables the unit to be adapted to installations requiring return air ducts or to be used as a return air plenum with a unit mounted filter and filter rack assembly.
All of the above ducted and ceiling concealed fan coil x units use variable speed dc inverter motor fans as such they are highly efficient very quiet and long lasting.
42da ceiling furred in.
Ideal for installation in hotels apartments and other multi room buildings 42 series fan coils combine heating and cooling performance with easy low cost installation.
42dd vertical with galvanized casing.
The horizontal hideaway with plenum cpy fan coil unit includes a return air plenum for above ceiling mounting.
42de ceiling with galvanized casing.
42dh horizontal direct drive blower coil.
42dc ceiling furred in with plenum.
Wherever possible fan coils should be installed in closets or above drywall ceilings which provide the necessary transmission loss.
There are two main ducts supply and return which will go around the building to supply the various rooms.
A fan coil unit fcu contains a fan which draws the air in a space into the unit then blows it over a cooling or heating coil.
Chilled water fan coil units for district cooling plant.
The fan coil units are connected to either a heating coil a cooling coil or both heating and cooling coil.