Are the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage.
Fire door inspection form.
We are certified to perform detailed 13 points fire doors inspection.
Fire damper commissioning fire smoke door inspection maintenance fire and smoke door repair and installation fire door labeling firestop survey installation above ceiling firestop survey fire barrier survey statement of conditions.
Annual inspection and testing of fire and smoke door assemblies.
Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained.
Dhi s fire egress door assembly inspection program is a four part program combining education certification risk management and advocacy.
To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist.
The assembly is composed of the fire door frame fire exit hardware door closers hinges locks door bolts and other door components that when combined provide varying degrees of fire protection that is contingent on the door fire rating e g.
Is the door free from missing or broken parts.
Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify.
Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities.
The newest standard requires that fire rated doors be tested for functionality no less than annually and that a written record of the inspection be kept on file for the authority having jurisdiction ahj.
Does the active door leaf completely close when.
Use one form for each door and keep documentation for at least three years.
Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.
Is the clearance from the door edge to the frame no more than 1 8 inch.
In addition to all of the components of a fire door assembly.
It is recommended that a facility identify all doors to be inspected on a drawing layout of the facility to track inspections.
For fire doors and other opening protectives 2010 edition.
45 minutes 90 minutes.